{"product_id":"federal-pacific-nc0215-15-amp-2-pole-120-240v-stab-lok-thin-circuit-breaker","title":"Federal Pacific NC0215 15-Amp 2-Pole 120\/240V Stab-Lok Thin Circuit Breaker","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Federal Pacific Electric (FPE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e NC0215\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Circuit Breaker\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries \/ Type:\u003c\/strong\u003e Type NC \/ Stab-Lok\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAmperage:\u003c\/strong\u003e 15A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 2-Pole\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage:\u003c\/strong\u003e 120\/240VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterrupting Rating:\u003c\/strong\u003e 10kA (10,000 AIC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTrip Type:\u003c\/strong\u003e Thermal-Magnetic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTrip Functions:\u003c\/strong\u003e Long-Time \/ Instantaneous\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Type:\u003c\/strong\u003e Plug-In \/ Stab-Lok\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBreaker Style:\u003c\/strong\u003e Thin \/ Space-Saver Type NC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Width:\u003c\/strong\u003e 1\"\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWidth Per Pole:\u003c\/strong\u003e 1\/2\"\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Connection:\u003c\/strong\u003e Screw Connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWire Range:\u003c\/strong\u003e #14–#6 AWG Copper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Calibration:\u003c\/strong\u003e 40°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertification:\u003c\/strong\u003e CSA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e Compatible Federal Pacific \/ Stab-Lok load centers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e New\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer Status:\u003c\/strong\u003e Legacy \/ Discontinued\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnticipated Weight:\u003c\/strong\u003e \u003cstrong\u003e0.39 lb\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFederal Pacific NC0215\u003c\/strong\u003e is a \u003cstrong\u003e15-Amp, 2-pole, 120\/240V Type NC Stab-Lok circuit breaker\u003c\/strong\u003e designed for use in compatible Federal Pacific electrical panels and load centers.\u003c\/p\u003e\n\u003cp\u003eThe NC0215 features a compact \u003cstrong\u003ethin \/ space-saver design\u003c\/strong\u003e, providing a complete 2-pole breaker in an approximately \u003cstrong\u003e1-inch-wide body\u003c\/strong\u003e. Each pole occupies approximately 1\/2 inch, allowing the breaker to fit compatible Stab-Lok panels designed for Type NC breakers.\u003c\/p\u003e\n\u003cp\u003eThe NC0215 uses a \u003cstrong\u003eplug-in Stab-Lok connection\u003c\/strong\u003e and provides thermal-magnetic overload and short-circuit protection with a \u003cstrong\u003e10,000 AIC interrupting rating\u003c\/strong\u003e. It accepts \u003cstrong\u003e#14 through #6 AWG copper conductors\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis is \u003cstrong\u003enew legacy inventory\u003c\/strong\u003e intended primarily as an exact replacement for an existing Federal Pacific NC0215 in compatible Stab-Lok electrical equipment.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e15 Amp\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e2-Pole\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e120\/240VAC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10,000 AIC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFederal Pacific \u003cstrong\u003eStab-Lok\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eType NC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThin \/ space-saving configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApproximately \u003cstrong\u003e1-inch overall width\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1\/2-inch width per pole\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlug-in \/ Stab-Lok mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermal-magnetic protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLong-time and instantaneous trip functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e#14–#6 AWG copper conductor range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePart number \u003cstrong\u003eNC0215\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for compatible Federal Pacific Stab-Lok load centers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNew condition\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCondition\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eNew:\u003c\/strong\u003e Unused legacy inventory. Due to the age and discontinued status of this product, original packaging may not be included and the breaker or packaging may show minor signs of storage.\u003c\/p\u003e\n\u003ch3\u003eImportant Compatibility Information\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eNC0215 is a thin Type NC Stab-Lok circuit breaker rated 15A, 2-pole and 120\/240VAC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eBefore ordering, verify the \u003cstrong\u003eNC0215 part number, Type NC configuration, 15A rating, 2-pole configuration, 120\/240V rating, approximately 1-inch overall body width, and Stab-Lok connection\u003c\/strong\u003e against your existing breaker and panel.\u003c\/p\u003e\n\u003cp\u003eDo not select a replacement breaker based solely on amperage and pole count.\u003c\/p\u003e","brand":"Federal Pacific","offers":[{"title":"New","offer_id":44598807986241,"sku":"NC0215","price":60.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1099\/2006\/files\/NC0215_2571F__17471.webp?v=1789507063","url":"https:\/\/sonicelectric.com\/products\/federal-pacific-nc0215-15-amp-2-pole-120-240v-stab-lok-thin-circuit-breaker","provider":"Sonic Electric","version":"1.0","type":"link"}