{"product_id":"elco-4-0-10v-max-adjustability-new-construction-ic-airtight-housing","title":"Elco Lighting 4\" 0-10V Max. Adjustability New Construction IC Airtight Housing","description":"\u003cdiv class=\"lead-time-note\"\u003e\u003cp\u003e\u003cstrong\u003eSpecial Order Item:\u003c\/strong\u003e This is a special item that requires an extended 2-6 business day lead time.\u003c\/p\u003e\u003c\/div\u003e\u003cp\u003e\u003cstrong\u003eElco Lighting 4\" 0-10V Max. Adjustability New Construction IC Airtight Housing\u003c\/strong\u003e\u003c\/p\u003e\u003ch4\u003eProduct Details\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eWired for 0-10V Dimming\u003c\/li\u003e\n\u003cli\u003e120\/277V Input\u003c\/li\u003e\n\u003cli\u003eIntegrated collar allows for use with ⅝\" thick to 1 ½\" thick ceilings \u003c\/li\u003e\n\u003cli\u003eDouble Wall IC Airtight for direct contact with Insulation\u003c\/li\u003e\n\u003cli\u003eMeets restricted air flow requirements (per ASTM E-283)\u003c\/li\u003e\n\u003cli\u003eUL Listed (US and Canada) for direct contact with Insulation\u003c\/li\u003e\n\u003cli\u003eUL Listed (US and Canada) for Damp Locations\u003c\/li\u003e\n\u003cli\u003eUL Listed (US and Canada) for Wet Location with Wet Location Rated Inserts\u003c\/li\u003e\n\u003cli\u003eUL Listed (US and Canada) for Feed Through\u003c\/li\u003e\n\u003cli\u003eCA Title 24 Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eConstruction: ​​\u003c\/strong\u003e\u003cbr\u003e•  IC rated for direct contact with insulation, for use in IC or Non-IC conditions.\u003cbr\u003e•  Housing adjusts in frame to accommodate up to 1½\" ceiling thickness.\u003cbr\u003e•  Airtight housing with gasket to restrict airflow in accordance with ASTM E-283 air-tight requirements.\u003cbr\u003e•  Steel housing for greater heat dissipation.  Stamped galvanized steel frame.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInstallation: \u003c\/strong\u003eDesigned for ceiling plenums where 2x6 joists or taller joists are used. High strength swivel hanger bars can easily be nailed to joists. Maximum hole cutout is 4 1\/4\". Suitable for T-grid and drop ceiling applications. See installation sheet for detailed information.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eJunction Box: \u003c\/strong\u003ePositioned to accommodate straight conduit runs. Seven 1\/2\" trade size conduit knockouts, four 3\/4\" knockouts with pry-out knockout slots. 4 Romex pryouts with strain relief.  \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHanger Bars: \u003c\/strong\u003ePre-installed swivel hanger bars with TrueNail facilitate easy installation in regular lumber, engineered lumber, and laminated beams. Integral T-bar slots for easy installation in T-bars. Spans up to 24\" and can be repositioned 90°. Score lines allow for tool-free hanger bar size reduction. Integral leveling flange allows for single-person installation while aligning the housings with the joists.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eElectrical:\u003c\/strong\u003e Input Voltage: 120277V. \u003cstrong\u003eEmergency Backup: \u003c\/strong\u003eThe fixture becomes 120V only.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimmability:\u003c\/strong\u003e Dimmability based on lamp.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eLamp: \u003c\/strong\u003eDesigned for use with ELCO 4\" Pex Twist-On Trims and 0-10V Koto LED module\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eListings:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e     •  cULus Listed for US and Canada.\u003cbr\u003e•  UL Listed (US and Canada) for Damp Location.\u003cbr\u003e•  UL Listed (US and Canada) for Wet Location with select trims.\u003cbr\u003e•  UL Listed (US and Canada) for Feed Through.\u003cbr\u003e•  UL Listed (US and Canada) for Direct Contact with Insulation and Combustible Material.\u003cbr\u003e•  Airtight per ASTM E-283.\u003cbr\u003e•  Install a JA8-2025-E lamp for Title 24 Compliance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWarranty: \u003c\/strong\u003eELCO Lighting warrants products will be free from defects in materials and workmanship for a period of 5 years.\u003c\/p\u003e\u003ch4\u003eFeatures\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e5 Year Warranty\u003c\/li\u003e\n\u003cli\u003eAirtight\u003c\/li\u003e\n\u003cli\u003eDimmable\u003c\/li\u003e\n\u003cli\u003eIC Rated\u003c\/li\u003e\n\u003cli\u003eTitle 24 Compliant\u003c\/li\u003e\n\u003cli\u003eENERGY STAR\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElco Lighting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer Part Numbers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEL485ICDXA, EL485ICDXA-EM7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThe DX Koto System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120-277V, 120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEmergency Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmergency Battery Backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimming\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-10V\/Triac\/ELV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew Construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eSpecification Sheets \u0026amp; Installation Guides\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/elcolighting.com\/api\/spec-sheet\/4-0-10v-max-adjustability-new-construction-ic-airtight-housing\" target=\"_blank\" rel=\"noopener\"\u003eSpecification Sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.elcolighting.com\/s3fs-public\/dl-resource\/files\/ELCAT1060_B_Koto_System.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalog: The Koto System (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Elco Lighting","offers":[{"title":"120-277V \/ -","offer_id":51183729508417,"sku":"EL485ICDXA","price":41.49,"currency_code":"USD","in_stock":true},{"title":"120V \/ Emergency Battery Backup","offer_id":51183729541185,"sku":"EL485ICDXA-EM7","price":330.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1099\/2006\/files\/EL485ICDXA.png?v=1795628080","url":"https:\/\/sonicelectric.com\/products\/elco-4-0-10v-max-adjustability-new-construction-ic-airtight-housing","provider":"Sonic Electric","version":"1.0","type":"link"}